30
UCP
-
3901 Card Installation and Operation
SFP Socket Status Indicators
For further information about how to troubleshoot an issue, see
page 325.
All alarms and operational statuses can also be seen from Rollcall Logging pages. These
pages provide the live status of the card. Theses statuses are also logged when using a Log
Server. See
SFP Socket Status Indicators
Each SFP socket has a status indicator. If the LED is flashing, the link is down.
10/25G Ethernet SFP Socket Link LED Status Indicator
•
Red:
Fault, 3V3 regulator failure.
•
Green:
10G OK
•
Blue:
25G OK
Fiber Optic Handling
Never assume a fiber is dark. Never look directly into the end of a fiber cable. All people in
the area must wear laser safety glasses with side shields. See also
SELECT Button
Press to select this card for local control using the Densité frame’s
control panel. Through the Densité frame’s control panel, you can set
the card’s IP addresses of the Ethernet interfaces. See
using the Densité frame control panel to set the Card’s IP Addresses
USB Socket
Unused.
Reset Button
Performs a hardware reset of the card. Only use this feature during off
hours as this will result in an outage until the card has returned to
normal operation (Densité status LED becomes green).
a.Level 1 = lowest priority, greater than level 1 = higher priority. How the status indication priority
operates: The Densité status LED only shows the highest active priority condition at any given time.
When the condition that triggers a status is removed or is rectified, then the next lower status
indication priority that is currently active is shown.
Item
Description
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...