144
Essence Processing SDC
Logging - System
Where N is the input or Ethernet port number
.
To identify SFP 1 / 2, see
TIMESYNC_N_CLOCK_ADDRESS=
When
card is synchronized to a network PTP
grandmaster clock, this shows the
PTP grandmaster
clock’s IP address.
TIMESYNC_N_REQUEST_INTERVAL
=
When
card is synchronized to a network PTP
grandmaster clock, this shows the
interval between
PTP message.
TIMESYNC_N_REFERENCE=
When
card is synchronized to a network PTP
grandmaster clock, this shows which Ethernet port is
being used to receive the PTP clock source
.
FAN_STATUS
For the UCP
-
3901 Card only.
Logs the card’s cooling fan health.
OK:
The card’s fan is operating normally.
FAIL:
The card’s fan is not spinning, or is spinning too
slowly, or the fan cable is disconnected. Urgent
maintenance procedures must be considered: If this
alarm has been raised, the fan on the UCP
-
3901 card
DENSITE_CONTROLLER_STATUS
For the UCP
-
3901 Card only.
Reports the connection status of the Densité frame’s
controller card to the UCP
-
3901 card.
OK:
The UCP
-
3901 card has successfully connected to
the Densité frame’s controller.
Not Connected:
The UCP
-
3901 card did not connect
to the Densité frame’s controller or the UCP
-
3901
card has lost connection to the Densité frame’s
controller.
DENSITE_CONTROLLER_IP_ADDR
For the UCP
-
3901 Card only.
Reports the IP Address of the Densité frame’s
controller card. If the IP address is 0.0.0.0, then the
UCP
-
3901 card has not yet received the IP address
from the frame’s controller.
DENSITE_FRAME_SLOT
For the UCP
-
3901 Card only.
This is the slot number in which the UCP
-
3901 card is
located within the Densité Frame.
Log Field Parameter
Description
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...