175
UCP
-
3901
User Manual
Parameter
Description
MADI IO
Displays how input and output spigots are currently configured. See
Card Firmware/Software Version
, below, for information on how to
change this.
Where Am I
Causes the front-edge and rear panel LEDs to flash, allowing the card
to be easily identified.
Genlock
Select
Genlock
type:
Network:
use the network’s PTP clock. See
on page 178 for further configuration settings.
External Reference:
UCP-3901 only; use the reference signal found at
the
REF
connector on the card’s rear panel. See
Chassis Reference A
/
B:
use the reference signal supplied through
the IQ Modular frame’s references.
Freerun:
card is using its own clock with no reference to any other
source.
GUID
Displays the absolute unique identifier associated with the card.
Domain
R uses domains to partition a network; only nodes on the
same domain can communicate with one another. A domain is
uniquely identified with a number and a friendly name/alias.
Set an ID as required, then press
Take
to confirm the change.
Interface
Configuration
Displays the IP address for each of the Ethernet interfaces.
Card Firmware /
Software Version
Each software version contains multiple firmware images. These allow
different spigot input/output and flow standard combinations to be
selected.
Select the required software from the
Software Version
pane, then
select the firmware which provides the required combination of
inputs, outputs and flow standards from the list displayed on the
Firmware
pane.
Note
:
Restore
and
Restart
buttons are displayed
only when an item not currently installed is selected.
See
on page 176, for more information.
Click
Take
to restart the card and implement any changes made.
See
3901 / IQUCP25 / IQUCP50’s SDC Application
on page 309 for how to change the SDC application.
Installed 25G /
50G Licensed
Options
Shows the currently installed licensed card options. See See
on page 314 for how to
install a license.
Reset to Defaults
on Restart
Enable checkbox to cause any existing details stored on the module,
other than network IP settings, to be cleared down prior to restarting
, below, and
page 243 for more information.
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...