142
Essence Processing SDC
Logging - System
SLOT_WIDTH=
Logs the slot width. UCP
-
3901 / IQUCP25 / IQUCP50
cards are available in single, double, and triple width.
SLOT_START=
Logs the slot in the rack where the card is located.
POWER_USAGE=
Logs the power usage in watts and PR Units.
Note
: this cannot be deselected.
TEMP
_N_
CELSIUS=
Logs the temperature status of the FPGA in Celcius.
Note
: this cannot be deselected.
TEMP_
N
_NAME=
Logs the Temperature measurement name.
REFERENCE_
N
_SOURCE=
Logs the time reference source.
REFERENCE_
N
_STATE=
Logs the time reference value. Valid values are:
OK:Locked
OK:Input
WARN:Freerun
WARN:CrossLock
TIMESYNC_
N
_MODE=
Logs the time sync mode value. Valid values are:
Free running
: Card is using its own clock with no
reference to any other source.
PTP Multicast
: Card is synchronizing to a PTP
grandmaster clock using multicast network
messages.
PTP Unicast
: As PTP Multicast but using the delay
request. Reply messages are unicast to minimize
network traffic.
NTP
: Card clock is synchronized to an NTP clock.
Generally less precise than PTP.
TIMESYNC_
N
_NETWORK=
Logs the network port currently being used for
synchronization for UCP
-
3901 / IQUCP25 / IQUCP50
cards, dependent on the choice of interfaces made
on the Time Configuration page. If PTP and multiple
interfaces are enabled, the PTP synchronization will
switch ports if it doesn't see regular sync messages
on the port.
TIMESYNC_
N
_CLOCK_ID=
Logs the identification number of PTP clock being
used for synchronization. This is not necessarily the
grandmaster clock identity, as there can be
intermediate clocks between the grandmaster and
the card, depending on network configuration.
Log Field Parameter
Description
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...