Carrying Out a System Reset
Once all changes in the
System-Setup
template have been done, carry out a system reset.
During off hours when the system is not in use:
1 Click on the
System Reset
button. The
Confirm
button becomes active.
2 Click
Confirm
to perform a system reset.
Or click
Cancel
to abort the system reset.
Booting takes about 75 seconds to complete during which the card will be unavailable.
About the RollCall Address
About the RollCall Domain ID
Location
You can specify the multiviewer’s location details, to make it easier to
find where the multiviewer is located in the future. Maximum 64
characters. Click
or press
return
to save the name locally.
Notes
You can enter extra notes and information about the multiviewer
here. Up to 64 characters can be displayed in the notes field. Click
or press
return
to save the name locally.
Parameter
Description
Note:
RollCall address:
This is not an IP network address.
A RollCall address has the form: NNNN:UU:PP
where:
NNNN is the RollCall network number.
UU is the RollCall unit number.
PP is the multiviewer input number (01, 02, and so on).
Note:
RollCall Domain ID:
RollCall uses the concept of domains to partition a RollCall
network. Only those RollCall-enabled devices on the same
RollCall Domain can communicate with one another.
A domain is uniquely identified with a
Domain ID
number.
Domain ID
is also used by Orbit software when connecting to
an Multiviewer SDC.
• The
Domain ID
can typically be left at its default value, 100.
(Reserved for multiviewer RollCall traffic.)
• To reset the
Domain ID
to the default value of 100 click on
the
button.
To set the
Domain ID
, enter the Domain ID number in the text
box and click
to locally save the new setting.
Summary of Contents for IQUCP25
Page 8: ...8 Notices ...
Page 47: ...47 UCP 3901 User Manual IQUCP2504 2B3 IQUCP2505 3B3 IQUCP5000 2B3 ...
Page 52: ...52 IQUCP Card Installation and Operation Remote control using RollCall ...
Page 58: ...58 Connections and Cabling About HDMI Type Signal Connections ...
Page 70: ...70 Connecting to the Card s Configuration Interface Setting Values in RollCall ...
Page 167: ...167 UCP 3901 User Manual Ethernet Arcnet Not currently used ...
Page 246: ...246 MADI Processing SDC Ethernet Arcnet Ethernet Arcnet Not currently used ...