6-6
Chapter 6 TROUBLESHOOTING
HP-GL™ Command Mode Error Messages
Error message
Cause
Solution
ERROR 1 Instruction
not recognized
An unrecognizable instruction was executed. Execute a recognizable command.
Nose was nput to the plotter upon executon
of the software applcaton.
Press the [ENTER] key.
The software's output settngs have been
changed.
Configure the software for output by this
plotter.
Ensure that the software's nterface settngs
are correctly set.
The plotter's nterface settngs have been
changed.
Ensure that the plotter's nterface settngs
are correctly set.
ERROR 2 Wrong number
of parameters
A command was executed wth the wrong
number of parameters.
Execute the command wth the correct
number of parameters.
ERROR 3 Out of range
parameters
A command contanng an unusable
parameter was specified.
Execute the command wth ts parameters
specified within their permissible ranges.
ERROR 5 Unknown
character set
An unrecognizable character set was
specified.
Specify a recognizable character set.
ERROR 6
Position overflow
A command was executed wth coordnate
data that exceeds the effectve cuttng/
plottng area.
Execute the command wth ts coordnate
data specified within the effective cutting/
plottng area.
ERROR 7
Buffer overflow
The data beng nput exceeded the capacty
of the plotter's downloadable character
buffer, polygon buffer, etc.
Increase the buffer size.
ERROR 10 Invalid
I/O output request
Durng executon of an output command,
another output command was executed.
Check the program.
ERROR 11 Invalid
byte following ESC.
The ESC character was followed by an
nvald byte.
Check the program.
ERROR 12 Invalid
byte in I/O Control
A devce control command contanng an
nvald byte was receved.
Check the program.
ERROR 13 Out of
range I/O parameter
A parameter outsde of the permssble
numeric range was specified.
Check the program.
ERROR 14 Too many
I/O parameters
Too many nterface-related command
parameters were receved.
Check the program.
ERROR 15 Error in
I/O transmission
A framng error, party error or overrun error
occurred.
Change the RS-232C transmsson
condtons.
ERROR 16 I/O buffer
overflow
The interface buffer overflowed.
Change the RS-232C transmsson
condtons.
Summary of Contents for FC2250 Series
Page 1: ...USER S MANUAL MANUAL NO FC2250 UM 151 FC2250 SERIES CUTTING PRO...
Page 105: ...5 29 Chapter 5 FUNCTION SETTINGS AND OPERATIONS Cutting Plotting Conditions List...
Page 111: ...CHAPTER 6 TROUBLESHOOTING PRODUCT SUMMARY 6 1 Troubleshooting 6 2 Error Messages...
Page 121: ...CHAPTER 8 SPECIFICATIONS PRODUCT SUMMARY 8 1 Main Specifications 8 2 External Dimensions...
Page 130: ......