B-76
G60 Generator Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
F208
TEXT2: 2-CHARACTER ASCII TEXT
F213
TEXT32: 32-CHARACTER ASCII TEXT
F220
ENUMERATION: PUSHBUTTON MESSAGE PRIORITY
F222
ENUMERATION: TEST ENUMERATION
0 = Test Enumeration 0, 1 = Test Enumeration 1
F224
ENUMERATION: RATE TREND FOR FREQ RATE OF CHANGE
0 = Increasing, 1 = Decreasing, 2 = Bidirectional
F225
ENUMERATION: SPLIT PHASE PROTECTION MODE
0 = Over, 1 = Over-Under
F226
ENUMERATION: REMOTE INPUT/OUTPUT TRANSFER
METHOD
0 = None, 1 = GSSE, 2 = GOOSE
F227
ENUMERATION: RELAY SERVICE STATUS
0 = Unknown, 1 = Relay In Service, 2 = Relay Out Of Service
F230
ENUMERATION: DIRECTIONAL POLARIZING
0 = Voltage, 1 = Current, 2 = Dual
F231
ENUMERATION: POLARIZING VOLTAGE
0 = Calculated V0, 1 = Measured VX
F232
ENUMERATION: CONFIGURABLE GOOSE DATASET ITEMS
FOR TRANSMISSION
value
priority
0
Disabled
1
Normal
2
High Priority
value
GOOSE dataset item
0
None
1
GGIO1.ST.Ind1.q
2
GGIO1.ST.Ind1.stVal
3
GGIO1.ST.Ind2.q
4
GGIO1.ST.Ind2.stVal
↓
↓
255
GGIO1.ST.Ind128.q
256
GGIO1.ST.Ind128.stVal
257
MMXU1.MX.TotW.mag.f
258
MMXU1.MX.TotVAr.mag.f
259
MMXU1.MX.TotVA.mag.f
260
MMXU1.MX.TotPF.mag.f
261
MMXU1.MX.Hz.mag.f
262
MMXU1.MX.PPV.phsAB.cVal.mag.f
263
MMXU1.MX.PPV.phsAB.cVal.ang.f
264
MMXU1.MX.PPV.phsBC.cVal.mag.f
265
MMXU1.MX.PPV.phsBC.cVal.ang.f
266
MMXU1.MX.PPV.phsCA.cVal.mag.f
267
MMXU1.MX.PPV.phsCA.cVal.ang.f
268
MMXU1.MX.PhV.phsA.cVal.mag.f
269
MMXU1.MX.PhV.phsA.cVal.ang.f
270
MMXU1.MX.PhV.phsB.cVal.mag.f
271
MMXU1.MX.PhV.phsB.cVal.ang.f
272
MMXU1.MX.PhV.phsC.cVal.mag.f
273
MMXU1.MX.PhV.phsC.cVal.ang.f
274
MMXU1.MX.A.phsA.cVal.mag.f
275
MMXU1.MX.A.phsA.cVal.ang.f
276
MMXU1.MX.A.phsB.cVal.mag.f
277
MMXU1.MX.A.phsB.cVal.ang.f
278
MMXU1.MX.A.phsC.cVal.mag.f
279
MMXU1.MX.A.phsC.cVal.ang.f
280
MMXU1.MX.A.neut.cVal.mag.f
281
MMXU1.MX.A.neut.cVal.ang.f
282
MMXU1.MX.W.phsA.cVal.mag.f
283
MMXU1.MX.W.phsB.cVal.mag.f
284
MMXU1.MX.W.phsC.cVal.mag.f
285
MMXU1.MX.VAr.phsA.cVal.mag.f
286
MMXU1.MX.VAr.phsB.cVal.mag.f
287
MMXU1.MX.VAr.phsC.cVal.mag.f
288
MMXU1.MX.VA.phsA.cVal.mag.f
289
MMXU1.MX.VA.phsB.cVal.mag.f
290
MMXU1.MX.VA.phsC.cVal.mag.f
291
MMXU1.MX.PF.phsA.cVal.mag.f
292
MMXU1.MX.PF.phsB.cVal.mag.f
293
MMXU1.MX.PF.phsC.cVal.mag.f
294
MMXU2.MX.TotW.mag.f
295
MMXU2.MX.TotVAr.mag.f
296
MMXU2.MX.TotVA.mag.f
297
MMXU2.MX.TotPF.mag.f
298
MMXU2.MX.Hz.mag.f
299
MMXU2.MX.PPV.phsAB.cVal.mag.f
300
MMXU2.MX.PPV.phsAB.cVal.ang.f
301
MMXU2.MX.PPV.phsBC.cVal.mag.f
302
MMXU2.MX.PPV.phsBC.cVal.ang.f
value
GOOSE dataset item
Summary of Contents for G60 UR Series
Page 2: ......
Page 4: ......
Page 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Page 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 634: ...x G60 Generator Protection System GE Multilin INDEX ...