GE Multilin
G60 Generator Protection System
A-7
APPENDIX A
A.1 PARAMETER LISTS
A
7274
SRC 4 Qa
Vars
Source 4 phase A reactive power
7276
SRC 4 Qb
Vars
Source 4 phase B reactive power
7278
SRC 4 Qc
Vars
Source 4 phase C reactive power
7280
SRC 4 S
VA
Source 4 three-phase apparent power
7282
SRC 4 Sa
VA
Source 4 phase A apparent power
7284
SRC 4 Sb
VA
Source 4 phase B apparent power
7286
SRC 4 Sc
VA
Source 4 phase C apparent power
7288
SRC 4 PF
---
Source 4 three-phase power factor
7289
SRC 4 Phase A PF
---
Source 4 phase A power factor
7290
SRC 4 Phase B PF
---
Source 4 phase B power factor
7291
SRC 4 Phase C PF
---
Source 4 phase C power factor
7552
SRC 1 Frequency
Hz
Source 1 frequency
7553
SRC 2 Frequency
Hz
Source 2 frequency
7554
SRC 3 Frequency
Hz
Source 3 frequency
7555
SRC 4 Frequency
Hz
Source 4 frequency
9216
Synchchk 1 Delta V
Volts
Synchrocheck 1 delta voltage
9218
Synchchk 1 Delta F
Hz
Synchrocheck 1 delta frequency
9219
Synchchk 1 Delta Phs
Degrees
Synchrocheck 1 delta phase
9220
Synchchk 2 Delta V
Volts
Synchrocheck 2 delta voltage
9222
Synchchk 2 Delta F
Hz
Synchrocheck 2 delta frequency
9223
Synchchk 2 Delta Phs
Degrees
Synchrocheck 2 delta phase
9536
PMU 1 Va Mag
Volts
Phasor measurement unit 1 phase A voltage magnitude
9538
PMU 1 Va Angle
Degrees
Phasor measurement unit 1 phase A voltage angle
9539
PMU 1 Vb Mag
Volts
Phasor measurement unit 1 phase B voltage magnitude
9541
PMU 1 Vb Angle
Degrees
Phasor measurement unit 1 phase B voltage angle
9542
PMU 1 Vc Mag
Volts
Phasor measurement unit 1 phase C voltage magnitude
9544
PMU 1 Vc Angle
Degrees
Phasor measurement unit 1 phase C voltage angle
9545
PMU 1 Vx Mag
Volts
Phasor measurement unit 1 auxiliary voltage magnitude
9547
PMU 1 Vx Angle
Degrees
Phasor measurement unit 1 auxiliary voltage angle
9548
PMU 1 V1 Mag
Volts
Phasor measurement unit 1 positive-sequence voltage magnitude
9550
PMU 1 V1 Angle
Degrees
Phasor measurement unit 1 positive-sequence voltage angle
9551
PMU 1 V2 Mag
Volts
Phasor measurement unit 1 negative-sequence voltage magnitude
9553
PMU 1 V2 Angle
Degrees
Phasor measurement unit 1 negative-sequence voltage angle
9554
PMU 1 V0 Mag
Volts
Phasor measurement unit 1 zero-sequence voltage magnitude
9556
PMU 1 V0 Angle
Degrees
Phasor measurement unit 1 zero-sequence voltage angle
9557
PMU 1 Ia Mag
Amps
Phasor measurement unit 1 phase A current magnitude
9559
PMU 1 Ia Angle
Degrees
Phasor measurement unit 1 phase A current angle
9560
PMU 1 Ib Mag
Amps
Phasor measurement unit 1 phase B current magnitude
9562
PMU 1 Ib Angle
Degrees
Phasor measurement unit 1 phase B current angle
9563
PMU 1 Ic Mag
Amps
Phasor measurement unit 1 phase C current magnitude
9565
PMU 1 Ic Angle
Degrees
Phasor measurement unit 1 phase C current angle
9566
PMU 1 Ig Mag
Amps
Phasor measurement unit 1 ground current magnitude
9568
PMU 1 Ig Angle
Degrees
Phasor measurement unit 1 ground current angle
9569
PMU 1 I1 Mag
Amps
Phasor measurement unit 1 positive-sequence current magnitude
9571
PMU 1 I1 Angle
Degrees
Phasor measurement unit 1 positive-sequence current angle
9572
PMU 1 I2 Mag
Amps
Phasor measurement unit 1 negative-sequence current magnitude
9574
PMU 1 I2 Angle
Degrees
Phasor measurement unit 1 negative-sequence current angle
Table A–1: FLEXANALOG DATA ITEMS (Sheet 7 of 10)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for G60 UR Series
Page 2: ......
Page 4: ......
Page 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Page 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 634: ...x G60 Generator Protection System GE Multilin INDEX ...