6303
SRC 3 I_2 Mag
Degrees
Source 3 negative-sequence current magnitude
6305
SRC 3 I_2 Angle
Amps
Source 3 negative-sequence current angle
6306
SRC 3 Igd Mag
Degrees
Source 3 differential ground current magnitude
6308
SRC 3 Igd Angle
Amps
Source 3 differential ground current angle
6336
SRC 4 Ia RMS
Amps
Source 4 phase A current RMS
6338
SRC 4 Ib RMS
Amps
Source 4 phase B current RMS
6340
SRC 4 Ic RMS
Amps
Source 4 phase C current RMS
6342
SRC 4 In RMS
Amps
Source 4 neutral current RMS
6344
SRC 4 Ia Mag
Amps
Source 4 phase A current magnitude
6346
SRC 4 Ia Angle
Degrees
Source 4 phase A current angle
6347
SRC 4 Ib Mag
Amps
Source 4 phase B current magnitude
6349
SRC 4 Ib Angle
Degrees
Source 4 phase B current angle
6350
SRC 4 Ic Mag
Amps
Source 4 phase C current magnitude
6352
SRC 4 Ic Angle
Degrees
Source 4 phase C current angle
6353
SRC 4 In Mag
Amps
Source 4 neutral current magnitude
6355
SRC 4 In Angle
Degrees
Source 4 neutral current angle
6356
SRC 4 Ig RMS
Amps
Source 4 ground current RMS
6358
SRC 4 Ig Mag
Degrees
Source 4 ground current magnitude
6360
SRC 4 Ig Angle
Amps
Source 4 ground current angle
6361
SRC 4 I_0 Mag
Degrees
Source 4 zero-sequence current magnitude
6363
SRC 4 I_0 Angle
Amps
Source 4 zero-sequence current angle
6364
SRC 4 I_1 Mag
Degrees
Source 4 positive-sequence current magnitude
6366
SRC 4 I_1 Angle
Amps
Source 4 positive-sequence current angle
6367
SRC 4 I_2 Mag
Degrees
Source 4 negative-sequence current magnitude
6369
SRC 4 I_2 Angle
Amps
Source 4 negative-sequence current angle
6370
SRC 4 Igd Mag
Degrees
Source 4 differential ground current magnitude
6372
SRC 4 Igd Angle
Amps
Source 4 differential ground current angle
6656
SRC 1 Vag RMS
Volts
Source 1 phase AG voltage RMS
6658
SRC 1 Vbg RMS
Volts
Source 1 phase BG voltage RMS
6660
SRC 1 Vcg RMS
Volts
Source 1 phase CG voltage RMS
6662
SRC 1 Vag Mag
Volts
Source 1 phase AG voltage magnitude
6664
SRC 1 Vag Angle
Degrees
Source 1 phase AG voltage angle
6665
SRC 1 Vbg Mag
Volts
Source 1 phase BG voltage magnitude
6667
SRC 1 Vbg Angle
Degrees
Source 1 phase BG voltage angle
6668
SRC 1 Vcg Mag
Volts
Source 1 phase CG voltage magnitude
6670
SRC 1 Vcg Angle
Degrees
Source 1 phase CG voltage angle
6671
SRC 1 Vab RMS
Volts
Source 1 phase AB voltage RMS
6673
SRC 1 Vbc RMS
Volts
Source 1 phase BC voltage RMS
6675
SRC 1 Vca RMS
Volts
Source 1 phase CA voltage RMS
6677
SRC 1 Vab Mag
Volts
Source 1 phase AB voltage magnitude
6679
SRC 1 Vab Angle
Degrees
Source 1 phase AB voltage angle
6680
SRC 1 Vbc Mag
Volts
Source 1 phase BC voltage magnitude
6682
SRC 1 Vbc Angle
Degrees
Source 1 phase BC voltage angle
6683
SRC 1 Vca Mag
Volts
Source 1 phase CA voltage magnitude
6685
SRC 1 Vca Angle
Degrees
Source 1 phase CA voltage angle
6686
SRC 1 Vx RMS
Volts
Source 1 auxiliary voltage RMS
6688
SRC 1 Vx Mag
Volts
Source 1 auxiliary voltage magnitude
Table A–1: FLEXANALOG DATA ITEMS (Sheet 3 of 10)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for G60 UR Series
Page 2: ......
Page 4: ......
Page 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Page 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 634: ...x G60 Generator Protection System GE Multilin INDEX ...