GE Multilin
G60 Generator Protection System
B-67
APPENDIX B
B.4 MEMORY MAPPING
B
F112
ENUMERATION: RS485 BAUD RATES
F113
ENUMERATION: PARITY
0 = None, 1 = Odd, 2 = Even
F114
ENUMERATION: IRIG-B SIGNAL TYPE
0 = None, 1 = DC Shift, 2 = Amplitude Modulated
F115
ENUMERATION: BREAKER STATUS
0 = Auxiliary A, 1 = Auxiliary B
F116
ENUMERATION: NEUTRAL OVERVOLTAGE CURVES
0 = Definite Time, 1 = FlexCurve™ A, 2 = FlexCurve™ B,
3 = FlexCurve™ C
F117
ENUMERATION: NUMBER OF OSCILLOGRAPHY RECORDS
0 = 1
×
72 cycles, 1 = 3
×
36 cycles, 2 = 7
×
18 cycles, 3 = 15
×
9 cycles
F118
ENUMERATION: OSCILLOGRAPHY MODE
0 = Automatic Overwrite, 1 = Protected
F119
ENUMERATION: FLEXCURVE™ PICKUP RATIOS
F120
ENUMERATION: DISTANCE SHAPE
0 = Mho, 1 = Quad
F122
ENUMERATION: ELEMENT INPUT SIGNAL TYPE
0 = Phasor, 1 = RMS
F123
ENUMERATION: CT SECONDARY
0 = 1 A, 1 = 5 A
bitmask
value
bitmask
value
bitmask
value
0
300
4
9600
8
115200
1
1200
5
19200
9
14400
2
2400
6
38400
10
28800
3
4800
7
57600
11
33600
mask
value
mask
value
mask
value
mask
value
0
0.00
30
0.88
60
2.90
90
5.90
1
0.05
31
0.90
61
3.00
91
6.00
2
0.10
32
0.91
62
3.10
92
6.50
3
0.15
33
0.92
63
3.20
93
7.00
4
0.20
34
0.93
64
3.30
94
7.50
5
0.25
35
0.94
65
3.40
95
8.00
6
0.30
36
0.95
66
3.50
96
8.50
7
0.35
37
0.96
67
3.60
97
9.00
8
0.40
38
0.97
68
3.70
98
9.50
9
0.45
39
0.98
69
3.80
99
10.00
10
0.48
40
1.03
70
3.90
100
10.50
11
0.50
41
1.05
71
4.00
101
11.00
12
0.52
42
1.10
72
4.10
102
11.50
13
0.54
43
1.20
73
4.20
103
12.00
14
0.56
44
1.30
74
4.30
104
12.50
15
0.58
45
1.40
75
4.40
105
13.00
16
0.60
46
1.50
76
4.50
106
13.50
17
0.62
47
1.60
77
4.60
107
14.00
18
0.64
48
1.70
78
4.70
108
14.50
19
0.66
49
1.80
79
4.80
109
15.00
20
0.68
50
1.90
80
4.90
110
15.50
21
0.70
51
2.00
81
5.00
111
16.00
22
0.72
52
2.10
82
5.10
112
16.50
23
0.74
53
2.20
83
5.20
113
17.00
24
0.76
54
2.30
84
5.30
114
17.50
25
0.78
55
2.40
85
5.40
115
18.00
26
0.80
56
2.50
86
5.50
116
18.50
27
0.82
57
2.60
87
5.60
117
19.00
28
0.84
58
2.70
88
5.70
118
19.50
29
0.86
59
2.80
89
5.80
119
20.00
Summary of Contents for G60 UR Series
Page 2: ......
Page 4: ......
Page 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Page 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 634: ...x G60 Generator Protection System GE Multilin INDEX ...