A-4
G60 Generator Protection System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
6690
SRC 1 Vx Angle
Degrees
Source 1 auxiliary voltage angle
6691
SRC 1 V_0 Mag
Volts
Source 1 zero-sequence voltage magnitude
6693
SRC 1 V_0 Angle
Degrees
Source 1 zero-sequence voltage angle
6694
SRC 1 V_1 Mag
Volts
Source 1 positive-sequence voltage magnitude
6696
SRC 1 V_1 Angle
Degrees
Source 1 positive-sequence voltage angle
6697
SRC 1 V_2 Mag
Volts
Source 1 negative-sequence voltage magnitude
6699
SRC 1 V_2 Angle
Degrees
Source 1 negative-sequence voltage angle
6720
SRC 2 Vag RMS
Volts
Source 2 phase AG voltage RMS
6722
SRC 2 Vbg RMS
Volts
Source 2 phase BG voltage RMS
6724
SRC 2 Vcg RMS
Volts
Source 2 phase CG voltage RMS
6726
SRC 2 Vag Mag
Volts
Source 2 phase AG voltage magnitude
6728
SRC 2 Vag Angle
Degrees
Source 2 phase AG voltage angle
6729
SRC 2 Vbg Mag
Volts
Source 2 phase BG voltage magnitude
6731
SRC 2 Vbg Angle
Degrees
Source 2 phase BG voltage angle
6732
SRC 2 Vcg Mag
Volts
Source 2 phase CG voltage magnitude
6734
SRC 2 Vcg Angle
Degrees
Source 2 phase CG voltage angle
6735
SRC 2 Vab RMS
Volts
Source 2 phase AB voltage RMS
6737
SRC 2 Vbc RMS
Volts
Source 2 phase BC voltage RMS
6739
SRC 2 Vca RMS
Volts
Source 2 phase CA voltage RMS
6741
SRC 2 Vab Mag
Volts
Source 2 phase AB voltage magnitude
6743
SRC 2 Vab Angle
Degrees
Source 2 phase AB voltage angle
6744
SRC 2 Vbc Mag
Volts
Source 2 phase BC voltage magnitude
6746
SRC 2 Vbc Angle
Degrees
Source 2 phase BC voltage angle
6747
SRC 2 Vca Mag
Volts
Source 2 phase CA voltage magnitude
6749
SRC 2 Vca Angle
Degrees
Source 2 phase CA voltage angle
6750
SRC 2 Vx RMS
Volts
Source 2 auxiliary voltage RMS
6752
SRC 2 Vx Mag
Volts
Source 2 auxiliary voltage magnitude
6754
SRC 2 Vx Angle
Degrees
Source 2 auxiliary voltage angle
6755
SRC 2 V_0 Mag
Volts
Source 2 zero-sequence voltage magnitude
6757
SRC 2 V_0 Angle
Degrees
Source 2 zero-sequence voltage angle
6758
SRC 2 V_1 Mag
Volts
Source 2 positive-sequence voltage magnitude
6760
SRC 2 V_1 Angle
Degrees
Source 2 positive-sequence voltage angle
6761
SRC 2 V_2 Mag
Volts
Source 2 negative-sequence voltage magnitude
6763
SRC 2 V_2 Angle
Degrees
Source 2 negative-sequence voltage angle
6784
SRC 3 Vag RMS
Volts
Source 3 phase AG voltage RMS
6786
SRC 3 Vbg RMS
Volts
Source 3 phase BG voltage RMS
6788
SRC 3 Vcg RMS
Volts
Source 3 phase CG voltage RMS
6790
SRC 3 Vag Mag
Volts
Source 3 phase AG voltage magnitude
6792
SRC 3 Vag Angle
Degrees
Source 3 phase AG voltage angle
6793
SRC 3 Vbg Mag
Volts
Source 3 phase BG voltage magnitude
6795
SRC 3 Vbg Angle
Degrees
Source 3 phase BG voltage angle
6796
SRC 3 Vcg Mag
Volts
Source 3 phase CG voltage magnitude
6798
SRC 3 Vcg Angle
Degrees
Source 3 phase CG voltage angle
6799
SRC 3 Vab RMS
Volts
Source 3 phase AB voltage RMS
6801
SRC 3 Vbc RMS
Volts
Source 3 phase BC voltage RMS
6803
SRC 3 Vca RMS
Volts
Source 3 phase CA voltage RMS
6805
SRC 3 Vab Mag
Volts
Source 3 phase AB voltage magnitude
Table A–1: FLEXANALOG DATA ITEMS (Sheet 4 of 10)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for G60 UR Series
Page 2: ......
Page 4: ......
Page 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Page 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 634: ...x G60 Generator Protection System GE Multilin INDEX ...