![background image](http://html.mh-extra.com/html/ge/druck-adts-505/druck-adts-505_user-manual_132652092.webp)
6 - 12
Reference and Specification
K0260 Issue No. 8
[Units]
•
The list of units in the set-up menu divide into aeronautical units and units of pressure
measurement. The available units are:
Aeronautical units
ft and kts (ft/min) (includes Mach)
m and km/h (m/min) (includes Mach)
m and mph (m/s) (includes Mach)
m and km/h (hm/min) (includes Mach)
Units of pressure measurement
mbar
inH
2
O 60°F
inHg
psi
mmHg
hPa
inH
2
O 4°C
kPa
inH
2
O 20°C
Selecting [Units] from the main menu displays the three available sets of units, to change
the available sets, press
SETUP
and select:
[Setup units]
Select a parameter to change (i.e., ALT/Ps), the current
unit in [brackets].
The display shows units of altitude: ft or metres and
pressure units. Similarly, selecting the other
parameters causes the display to show appropriate
units. After selecting the required units, select {Save
Settings} and then repeatedly press
CLEAR/QUIT
to
return to the main menu.
Summary of Contents for Druck ADTS 505
Page 1: ...GE Measurement Control Druck ADTS 505 Air Data Test Set User Manual K0260 ...
Page 14: ...xii K0260 Issue No 8 Druck ADTS 505 User Manual ...
Page 54: ...3 26 Operation K0260 Issue No 8 ...
Page 55: ...Druck ADTS 505 User Manual 3 27 K0260 Issue No 8 3 ...
Page 56: ...3 28 Operation K0260 Issue No 8 ...
Page 66: ...5 4 Testing and Fault Finding K0260 Issue No 8 FIGURE 5 1 FAULT FINDING CHART ...
Page 80: ...5 18 Testing and Fault Finding K0260 Issue No 8 Intentionally left blank ...
Page 124: ...6 44 Reference and Specification K0260 Issue No 8 Intentionally left blank ...