Biacore T100 Software Handbook BR-1006-48 Edition AE
8.1 Requirements for concentration evaluation .........................139
8.2 Evaluating calibrated concentration analyses .....................140
8.2.1 Calibration curves...................................................................................140
8.2.2 Control samples ......................................................................................142
8.2.3 Samples ......................................................................................................143
8.2.4 Custom models for calibration curves ..........................................144
8.2.5 Evaluating combined result sets.....................................................144
8.3 Evaluating calibration-free measurements ..........................145
8.3.1 Selecting samples...................................................................................146
8.3.2 Removing disturbed data....................................................................149
8.3.3 Performing the evaluation..................................................................149
8.3.4 Interpreting the results.........................................................................150
8.3.5 Fitting model.............................................................................................151
Kinetics and affinity analysis
9.1 Requirements for kinetics and affinity evaluation ...............154
9.2 Evaluating kinetics and affinity in single mode ....................155
9.2.1 Basic procedure ......................................................................................155
9.2.2 Multiple ligand densities......................................................................162
9.3 Batch mode evaluation .............................................................163
9.4 Quality assessment for kinetics evaluation ..........................164
9.4.1 The Quality Control tab ........................................................................164
9.4.2 Statistical parameters ..........................................................................168
9.4.3 Components of the fit ...........................................................................170
9.4.4 Check kinetic data ..................................................................................170
9.5 Quality assessment for affinity evaluation ...........................172
9.6 Summarizing kinetics and affinity results .............................173
9.6.1 Creating kinetic summaries ...............................................................173
9.6.2 Basic summary presentation ............................................................173
9.6.3 On-off rate maps.....................................................................................176
9.7 Curve fitting principles ..............................................................177
9.7.1 Fitting procedure ....................................................................................177
9.7.2 Local and global parameters ............................................................178
9.8 Predefined models ......................................................................179
9.8.1 Kinetics – 1:1 binding............................................................................180
9.8.2 Kinetics – Bivalent Analyte .................................................................181
9.8.3 Kinetics – Heterogeneous Analyte ..................................................182
9.8.4 Kinetics – Heterogeneous Ligand....................................................184
9.8.5 Kinetics – Two State Reaction...........................................................186
9.8.6 Affinity – Steady State 1:1...................................................................188
9.9 Creating and editing models ....................................................188
9.9.1 Interaction models for kinetics .........................................................189
9.9.2 Equation models for kinetics .............................................................194
9.9.3 Models for steady state affinity ........................................................195
Summary of Contents for Biacore T100
Page 1: ...GE Healthcare Biacore T100 Software Handbook ...
Page 2: ......
Page 8: ...8 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 13: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 13 Control Software ...
Page 14: ...14 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 30: ...3 Manual run 3 4 Ending a manual run 30 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 103: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 103 Evaluation Software ...
Page 104: ...104 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 207: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 207 Appendices ...
Page 208: ...208 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 236: ...236 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 237: ......