2 Control Software – general features
2.3 Basic operation
22
Biacore T100 Software Handbook BR-1006-48 Edition AE
automatically put in standby mode at the end of a run. Use the menu option if
standby has been stopped and you want to restart it.
Stop Standby
stops standby mode.
Eject Rack
ejects the rack tray from the sample compartment. The rack may be
ejected during setup for wizard- and method-based runs, and at any time
during a manual run. Use the menu option or the toolbar button when you want
to eject the rack at any other time.
Rack Illumination
switches the blue illumination in the sample compartment on
or off. The illumination helps you to see in the sample compartment but does not
otherwise affect instrument function.
Insert Chip
and
Eject Chip
are used for docking and undocking the sensor chip
respectively. More details are given in Chapter 3 of the Biacore T100 Instrument
Handbook.
Set Temperature
sets the sample compartment and analysis temperature.
More details are given in Chapter 3 of the Biacore T100 Instrument Handbook.
Preferences
controls aspects of file storage and data import (see Section 2.4).
More Tools
provides access to maintenance, test and service tools. Details are
given in Appendix B of the Biacore T100 Instrument Handbook.
2.3.7
Right-click menus
Right-clicking with the mouse in some windows opens context menus specific
for the window.
Sensorgram window
Scale
opens the same dialog as the
View:Scale
option (Section 2.3.4).
Copy Graph
copies the sensorgram window exactly as displayed to the
Windows clipboard. Use this option to insert a copy of the sensorgram window
into other programs such as presentation software.
Export Curves
exports data for the currently displayed curves to a text file.
Entire curves are exported regardless of the scale of the display. The exported
data includes report points and event marker times if these are displayed in the
sensorgram window. See Appendix A for more details of the export format.
Gridlines
controls display of gridlines in the sensorgram window.
WARNING!
The rack tray automatically moves into the instrument 60
seconds after it has been ejected. A timer in the dialog indicates when the
rack tray will be automatically moved into the instrument.
Summary of Contents for Biacore T100
Page 1: ...GE Healthcare Biacore T100 Software Handbook ...
Page 2: ......
Page 8: ...8 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 13: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 13 Control Software ...
Page 14: ...14 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 30: ...3 Manual run 3 4 Ending a manual run 30 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 103: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 103 Evaluation Software ...
Page 104: ...104 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 207: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 207 Appendices ...
Page 208: ...208 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 236: ...236 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 237: ......