7 Data presentation tools
7.1 Sensorgram items
122
Biacore T100 Software Handbook BR-1006-48 Edition AE
7.1.1
Selecting sensorgrams for display
The selector bar at the top of the window controls which sensorgrams will be
displayed.
•
Curve name
lists the type of sensorgram (active, reference, reference
subtracted and solvent corrected where applicable).
•
Assay Step Purpose
filters the sensorgram according to the assay step
purpose.
•
Cycle
lists all the cycles in the result set. When multiple files are open,
cycles are identified with two numbers, one for the file in the result set and
one for the cycle within the file (thus cycle 1-10 is the 10
th
cycle in the first
file added to the result set; cycle 2-4 is the 4
th
cycle in the second file and
so on).
For each option, click the browse buttons to browse backwards or forwards
through the list, one item at a time.
Click the selector button to open the list for selecting one or more items. Drag
with the mouse or use shift-click to select contiguous multiple items. Use
control-click to select non-contiguous multiple items. To accept a selection, click
anywhere outside the list or press Enter.
7.1.2
Removing data
To remove data from the display, mark the section to be removed by dragging
with the right mouse button, then choose
Cut
from the right-click menu. The
data will be removed from the current sensorgram item only; no other windows
or evaluation items will be affected. This function can be useful for removing
injections with high bulk contributions (such as regeneration injections) or other
visual disturbances from the display.
Choose
Undo Cut
from the right-click menu to restore the removed data.
Summary of Contents for Biacore T100
Page 1: ...GE Healthcare Biacore T100 Software Handbook ...
Page 2: ......
Page 8: ...8 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 13: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 13 Control Software ...
Page 14: ...14 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 30: ...3 Manual run 3 4 Ending a manual run 30 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 103: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 103 Evaluation Software ...
Page 104: ...104 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 207: ...Biacore T100 Software Handbook BR 1006 48 Edition AE 207 Appendices ...
Page 208: ...208 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 236: ...236 Biacore T100 Software Handbook BR 1006 48 Edition AE ...
Page 237: ......