MCT-CM
105
NOTE:
The time is entered in a 24-hour format. To convert time from a 12-hour format (AM/PM) into 24-hour
format, add 12 to the hours for PM time. For example, 2pm will be a value of 14 (2 + 12) for hours.
A time of 5:30pm will be 17 hours, 30 minutes.
6.1.6
Setting Guaranteed Soak Limits
The guarantee soak limits are used to set the control tolerance for each loop during guaranteed soak steps
when in ramp/soak program operation. When a process variable deviates from its set point by more than its
soak limit value, the program timer will stop until the process variable re-enters the soak band. These limits
apply to every step in the program and only need to be set once.
To change a limit, touch the desired loop in the list, enter the new limit setting on the numeric keypad and press
‘Done’ when finished. The new limit value will then be shown in the list view for the selected control loop.
NOTE:
If soak limit is set too tight, i.e., a very small deviation value from set point, it could prevent the program
from operating as desired because the process may not be able to be controlled to such a tight limit
setting.
6.2 Starting an Automatic Ramp/Soak Program
All automated program operating functions are accessed via the Program Operation screen. This screen can
be accessed by pressing the “Program Operation” button on the Loop view or Overview screens or by pressing
the “Run” button on the program Entry screen.
Summary of Contents for MCT-CM
Page 20: ...MCT CM 20...
Page 24: ...MCT CM 24...
Page 45: ...MCT CM 45...
Page 187: ...MCT CM 187...
Page 227: ...MCT CM 227 A 4 Control Module Specifications Main CPU...
Page 228: ...MCT CM 228...
Page 229: ...MCT CM 229...
Page 230: ...MCT CM 230...
Page 231: ...MCT CM 231 Analog I O Card...
Page 232: ...MCT CM 232...
Page 233: ...MCT CM 233 Digital Input Card...
Page 234: ...MCT CM 234...
Page 235: ...MCT CM 235 Digital Output Card...
Page 236: ...MCT CM 236...
Page 237: ...MCT CM 237 Dual Communications Card Barcode and Remote Display Communication Cartridges...
Page 238: ...MCT CM 238 A 5 Power Supply Specifications...
Page 239: ...MCT CM 239...
Page 240: ...MCT CM 240 A 6 Power On Delay Relay Specifications GE1A C10HA110...
Page 241: ...MCT CM 241...