10.1 Service
The service counters provide service interval alerts and life total service numbers for each of the digital outputs
available on the MCT control module. The service intervals (counter set points) are adjustable and can be set
to match service intervals for equipment operated by the MCT.
Two service alert set points are provided for each output of the MCT. One service alert is available for the
number of times each output turns on and is adjustable from 0 to 4,000,000,000 cycles. The second service
alerts is for ‘on’ time and is adjustable from 0.0 to 400,000,000.0 hours.
To adjust a counter set point, select the output from the list by touching its description. The current set point
for that output will be shown in the set point field at the bottom of the screen. Enter the new set point by touching
the set point field and press the ‘Done’ button on the numeric keypad when finished.
NOTE:
To adjust the cycle counter, you must be viewing the elapsed interval or life total counts for the
outputs. To adjust the set point for hours of operation, you must be viewing the elapsed run or total
life hours of the outputs. See section 10.1.1 Service Options.
When a service interval is exceeded, a service alert can be set to appear on the alarm screen. This alert will
notify the operator that service should be performed at the next available down period. However, the alert will
not be able to be cleared from the alarm screen until the service counter that has been exceeded is reset.
In order to determine which service counter has been elapsed, scan the list of outputs and look for the
‘Exceeded’ description. To clear the counter, select the output from the list and press the ‘Clear’ button. This
will clear the counter so that it can begin totalizing for the next service interval.
Summary of Contents for MCT-CM
Page 20: ...MCT CM 20...
Page 24: ...MCT CM 24...
Page 45: ...MCT CM 45...
Page 187: ...MCT CM 187...
Page 227: ...MCT CM 227 A 4 Control Module Specifications Main CPU...
Page 228: ...MCT CM 228...
Page 229: ...MCT CM 229...
Page 230: ...MCT CM 230...
Page 231: ...MCT CM 231 Analog I O Card...
Page 232: ...MCT CM 232...
Page 233: ...MCT CM 233 Digital Input Card...
Page 234: ...MCT CM 234...
Page 235: ...MCT CM 235 Digital Output Card...
Page 236: ...MCT CM 236...
Page 237: ...MCT CM 237 Dual Communications Card Barcode and Remote Display Communication Cartridges...
Page 238: ...MCT CM 238 A 5 Power Supply Specifications...
Page 239: ...MCT CM 239...
Page 240: ...MCT CM 240 A 6 Power On Delay Relay Specifications GE1A C10HA110...
Page 241: ...MCT CM 241...