MCT-CM
127
NOTE:
Make sure proper permissions are set at the FileWeb server for access/creation of directories and
read/write access. Also check root directory structure at Server to identify the actual root that was
created for the files since there can be additional layers created by the server and displayed in the path.
The DataWeb interface allows the MCT to transfer data to a web data base service using MySQL and Microsoft
IIS as a web platform. The MCT can interface directly to a local or Web data base (Cloud) thereby allowing
access to any system globally without any special “client” applications required to view the data. This allows
the MCT to share data with local or global manufacturing systems by storing data directly to a manufacturing
database. The MCT supports https:// (secure) transfer of data.
MCT Field Setup
DataWeb Server Setup
Type = DataWeb
FileWeb server setup (see Appendix section A.2 FTP,
FileWeb,
DataWeb
Requirements/Installation
for
additional information).
IP Add =
https://fdctuil.com/FDDataService.svc
Actual named address of DataWeb server/service.
User = userName
Actual user name for login at FileWeb server (required).
This is the directory where the database structure will
reside on the server. The MCT will use this directory path
for sending data to the database.
Password = userPassword
Actual password for login at DataWeb server (required).
Server = not used
The directory where the database exists uses the
userName as the default location for data storage.
Port = not used
Data logging screen entries:
ID#1 = unit specific identifier
ID#2 = unit specific identifier
(see section 8.2 Starting/Stopping Data
Logging)
Used as the unit identifiers by the remote database in
order to store the data sent from the MCT. At least one
field must contain an entry and should be unique to any
other MCT
’s that connect to the same server database.
NOTE:
An IT professional with experience is required for DataWeb server setup. Future Design Controls does
not support server-side programming or setup but can offer 3
rd
party resources to assist with or handle
complete server-side projects.
The DataWeb interface does not transfer complete files for backup like the FTP and FileWeb interfaces. The
DataWeb interface transfers records in real time based on the log setup interval at the MCT. When logging is
started at the MCT, data will begin transfer to the server-side site. Data will be transferred to the server at the
beginning of logging (one record) with additional records transferred based on the rate that the MCT data log
interval is set for.
If the data log interval rate is set for 60 seconds, the MCT will populate the database with a single set of records
(PV, SP, %Out determined by data log/server setup) once every 60 seconds. If the data log interval rate is set
for 120 seconds, the MCT will populate the database with a single set of records (PV, SP, %Out determined by
data log/server setup) once every 120 seconds. Data log intervals can be set as fast as 2 seconds since
buffering is used at the MCT for faster data log rates, but in this case the database would receive a total of 30
records once per minute (one record per second). Buffering for rates faster than 1 minute is used to reduce
access/overhead at the server side while still maintaining 2 second date/time stamps for database record
keeping.
Summary of Contents for MCT-CM
Page 20: ...MCT CM 20...
Page 24: ...MCT CM 24...
Page 45: ...MCT CM 45...
Page 187: ...MCT CM 187...
Page 227: ...MCT CM 227 A 4 Control Module Specifications Main CPU...
Page 228: ...MCT CM 228...
Page 229: ...MCT CM 229...
Page 230: ...MCT CM 230...
Page 231: ...MCT CM 231 Analog I O Card...
Page 232: ...MCT CM 232...
Page 233: ...MCT CM 233 Digital Input Card...
Page 234: ...MCT CM 234...
Page 235: ...MCT CM 235 Digital Output Card...
Page 236: ...MCT CM 236...
Page 237: ...MCT CM 237 Dual Communications Card Barcode and Remote Display Communication Cartridges...
Page 238: ...MCT CM 238 A 5 Power Supply Specifications...
Page 239: ...MCT CM 239...
Page 240: ...MCT CM 240 A 6 Power On Delay Relay Specifications GE1A C10HA110...
Page 241: ...MCT CM 241...