8-20
8.2 Scanner Section
NOTE: Wipe clean the lens cover glass using a lens
cleaning cloth (TORAY TORAYSEE or equivalent).
Use a lens cleaning fluid if it is available.
After installation, perform the following adjustments.
1) Menu 0344 “Lens Registration”
2) Menu 0345 “Optical Axis Adjustment”
3) Menu 0346 “Optical Magnification Calibration”
4) Menu 0347 “Focus Calibration”
5) Menu 0321 “Focus Position Adjustment”
6) Menu 0420 “Mask Position Adjustment”
Removal
1. Remove the scanner section rear cover
2. Loosen the screw and open the CTB23 circuit
board bracket.
Z
2
498
Lens Cover Glass
8.2.14
Conjugate Length Variable Motor (M201) Replacement
Z
2
020
Screw
Circuit Board Bracket