13-29
13.2 Distribution Unit
13
3. Remove the two pre-turning belts.
4. Remove two E-rings each then the roller and two
bearings each.
Installation
Installation is essentially in the reverse order of removal.
Removal
1. Remove the distribution unit
2. Disconnect the connector, release the locking
tabs and remove the sensor.
Installation
Installation is essentially in the reverse order of removal.
LII532
Pre-turning Belts (2)
LII533
E-rings (2)
Bearings (2)
Roller
13.2.8
Distribution Home Position Sensor (D661) Replacement
LII534
Connector
Locking
Tabs
Sensor (D661)