7-39
7.2 NC100AY Lower Feed Section
7
Installation
Installation is essentially in the reverse order of
removal.
NOTE: • Install the roller assembly so that the groove of the
eccentric pin is at right angle with the film feed
lane as shown.
• Perform “Magnetic Reading Adjustment”
Perform this adjustment after replacing the magnetic
head and/or opposite roller.
1. Perform Menu 0452 “NC100AY Magnetic
Information Reading”
2. If the result is “NG”, perform the following
adjustment.
<Adjustment>
1) Remove the bottom cover
2) Connect the carrier to the plug-in connector of the
scanner by using a extension harness and set the
carrier to the IX240 feed lane.
3) Loosen the screw securing the opposite roller.
4) Turn the eccentric pin 45 degrees clockwise and
perform Menu 0452.
5) If the result is still “NG”, repeat Menu 0452 with
the eccentric pin in 90 degrees clockwise, 45 and
90 degrees counterclockwise positions in this
order to find “OK” point.
6) Secure the opposite roller by tightening the screw.
7) Disconnect the extension cable and reinstall the
bottom cover.
Z
2
310
Screw
Roller Assembly
Eccentric Pin
Eccentric Pin
7.2.10
Magnetic Reading Adjustment
Z
2
311
Opposite Roller Screw
Eccentric Pin