3-58
3.2 Messages and Actions
W-2674
Replenisher cartridge empty.
Insert a new replenisher cartridge.
When the lower level sensor detected
“no solution in all tanks” within the
specified time after the valve was
opened.
(Causes of the error message)
1. An empty replenisher cartridge is
installed.
2. Faulty replenisher tank lower level
sensor system
3. Faulty replenisher cartridge setting
sensor (D721)
1. Install a new replenisher cartridge.
2.
3. Replace D721.
E-2675
P1R replenisher cartridge washing
valve (S728) or P1R replenisher
stirring valve (S731) malfunctions.
About 510 3R-size sheets can still be
printed without replenishment.
Consult your technical representative.
P1R replenisher upper level sensor
detects “no solution”
(Causes of the error message)
1. Faulty P1R stirring valve (S731)
2. Faulty P1R cartridge washing
valve (S728)
3. Faulty auto washing pump
(PU720)
4. Faulty P1R upper level sensor
(FS720)
5. Air “frapped in” the hose used for
washing pumps
1.
2.
3.
4.
5. Perform Menu 0621 “Auto
Cleaning Output Measurement/
Setting”.
E-2676
P2RA replenisher cartridge washing
valve (S729) malfunctions.
About 510 3R-size sheets can still be
printed without replenishment.
Consult your technical representative.
P2RA replenisher upper level sensor
detects “no solution”
(Causes of the error message)
1. Faulty P2RA cartridge washing
valve (S729)
2. Faulty auto washing pump
(PU720)
3. Faulty P2RA upper level sensor
(FS721)
4. Air “frapped in” the hose used for
washing pumps
1.
2.
3.
4. Perform Menu 0621 “Auto
Cleaning Output Measurement/
Setting”.
E-2677
P2RB replenisher cartridge washing
valve (S730) malfunctions.
About 510 3R-size sheets can still be
printed without replenishment.
Consult your technical representative.
P2RB replenisher upper level sensor
detects “no solution”
(Causes of the error message)
1. Faulty P2RB cartridge washing
valve (S730)
2. Faulty auto washing pump
(PU720)
3. Faulty P2RB upper level sensor
(FS722)
4. Air “frapped in” the hose used for
washing pumps
1.
2.
3.
4. Perform Menu 0621 “Auto
Cleaning Output Measurement/
Setting”.
W-2678
Sorter nearly full.
Collect prints from sorter.
“Sorter full” is detected.
(Causes of the error message)
1. Sorter is full.
2. Poorly connected or broken
harness between the sorter full
sensor (D811) and SWA4 on the
SWA20 circuit board
3. Faulty D811
4. Faulty SWA20 circuit board
1. Remove print(s) from the sorter.
2. Connect the harness correctly, or
repair or replace it.
3. Replace D811.
4. Replace the SWA20 circuit board.
W-2679
Sorter full.
Stop printing.
Collect prints from sorter.
“Sorter completely full” is detected.
(Causes of the error message)
1. Sorter is full.
2. Poorly connected or broken
harness between the sorter full
sensor (D811) and SWA4 on the
SWA20 circuit board
3. Faulty D811
4. Faulty SWA20 circuit board
1. Remove print(s) from the sorter.
2. Connect the harness correctly, or
repair or replace it.
3. Replace D811.
4. Replace the SWA20 circuit board.
No.
Message
Factor
Actions