3-68
3.2 Messages and Actions
W-4328
Wrong combination of film mask and
diffusion box.
Check combination of film mask and
diffusion box.
Incorrect combination of diffusion box
and mask
Replace the mask or diffusion box.
W-4330
The leading frame is not detected.
Check the selected film type and the
actual film.
Leading end frame cannot be
detected.
(Causes of the error message)
1. Excessively underexposed or
unexposed 135 film image
2. Excessively underexposed or
unexposed image with unexposed
frame detect level = 1 for IX240
1. Scan an excessively
underexposed frame with fixed
feed mode or MFC10AY. Stop the
leading end frame by pressing the
feed fine adjustment key when
fixed feed mode is selected.
2. Check the IX240 film image.
Select 2 or 3 for IX240 unexposed
frame detect level.
W-4331
The parameter to request pre-
scanning is incorrect.
Check the carrier, film mask and the
print size.
If this error persists, consult your
technical representative.
Unexpected parameter (0 etc.) at
prescanning demand
Proceed to “Print Size Registration”
and check that the paper size is
correct
W-4335
The scanner correction hasn’t been
performed with this carrier.
Perform the scanner correction.
Image has been scanned with a
carrier without scanner correction
being performed.
Perform the scanner correction in
pre-operational checks.
W-4336
The focus position adjustment is not
performed with this carrier.
Install the film mask to be used, and
then perform the focus position
adjustment.
Focus position adjustment has not
been executed for the installed
carrier.
Perform focus position adjustment
and register it.
W-4337
The mask is not installed or it is not
installed correctly.
Install the correct one.
If it exists, make sure to install it
correctly.
Mask not installed or unset mask bit
is detected
(Causes of the error message)
1. Mask not installed
2. Calibration mask installed
3. Improperly seated mask
4. Faulty mask sensor
1. Install the mask.
2. Replace the calibration mask with
the correct one.
3. Install the mask correctly.
4. Replace the MSB23 circuit board.
W-4341
The range for cropping is incorrect.
Perform cropping with the image.
Bordered is selected but cropping
frame exceeds original area.
Set the rotating angle to zero or
reduce the cropping frame.
W-4343
Pre-scan failed.
Perform it again.
If this error persists, consult your
technical representative.
Pre-scanning error (Returned value
error from mounted print)
If another error occurred at the same
time, take action for it.
If there is no other error at the same
time, check the value in “Mask
Position Adjustment”.
W-4344
Pre-scan failed.
Perform it again.
If this error persists, consult your
technical representative.
Pre-scanning error (Returned value
error from mounted print)
If another error occurred at the same
time, take action for it.
If there is no other error at the same
time, check the value in “Mask
Position Adjustment”.
W-4345
Fine-scan failed.
Perform it again.
If this error persists, consult your
technical representative.
Pre-scanning error (Returned value
error from mounted print)
If another error occurred at the same
time, take action for it.
If there is no other error at the same
time, check the value in “Mask
Position Adjustment”.
No.
Message
Factor
Actions