16-10
16.2 Processing Solution Replenishment System
Removal
1. Remove the processor front cover
.
2. Open the three clamps and pull out the filter.
3. Pinch the inlet and outlet hoses with the pinchcocks.
4. Loosen the two clamps and disconnect the hoses
from the filter.
Installation
Installation is essentially in the reverse order of removal.
NOTE: • Connect the hoses securely
• After installation, perform the following adjustment.
• Menu 0620 "Pump Output Measurement/Setting"
Removal
1. Move the water supply port assembly
.
2. Remove the lower connector cover
.
3. Disconnect the three pump connectors.
16.2.1
Replenisher Filter Replacement
LII697
Hoses (2)
Pinchcocks (2)
Clamps (2)
Filter
Clamps (3)
16.2.2
P1R/P2RA/P2RB Pump (PU721/PU722/PU723) Replacement
LII698
Connectors (3)
Screws (2)