3-85
3.2 Messages and Actions
3
NOTE 1: The refreshing backup can be restored (see Section 3.4).
E-4481
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-transmission 1 message
sending error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CTB23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4482
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-transmission 1 message
receiving error
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CTB23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4483
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-transmission 1 retry over
(Causes of the error message)
1. Noise in electric line
- Outside noise (static electricity,
radio transmission or power
supply-induced)
- Inside noise
2. System software overload (faulty
software)
3. Faulty CTB23 circuit board (CPU)
1. Click [OK] to clear the message.
2. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
3. Replace the circuit board.
E-4484
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-message delivery module
initializing error 1
(Causes of the error message)
1. Abnormal software
2. Faulty CTB23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4485
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-message delivery module
initializing error 2
(Causes of the error message)
1. Abnormal software
2. Faulty CTB23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4486
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-message delivery message
sending error
(Causes of the error message)
1. Abnormal software
2. Faulty CTB23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
E-4487
The control of the CTB circuit board
is abnormal.
Restart the system. If problems
persist, consult your technical
representative.
SKCTB-message delivery message
sending error 1
(Causes of the error message)
1. Abnormal software
2. Faulty CTB23 circuit board (CPU)
1. Restart the system software. If the
error occurs again, reinstall the
system software. (NOTE 1)
2. Replace the circuit board.
No.