3-124
3.2 Messages and Actions
NOTE 1: The refreshing backup can be restored
(See Section 3.4)
.
W-4869
Carrier is not installed correctly.
Install the carrier.
Abnormal NC100AY carrier operation
(Causes of the error message)
1. Carrier error such as film
remaining, carrier installed with
pressure cover open, etc.
1. Set the carrier to normal condition.
E-4870
A communication error occurred
between the maintenance and GMB
circuit boards.
Communication timeout between
maintenance and GMB23 circuit
board
(Causes of the error message)
1. Faulty 1394 communication
2. Poorly connected 1394 cable
3. Faulty GIE23 circuit board
1. Replace the cable.
2. Reconnect the cable correctly.
3. Replace the circuit board.
W-4871
There are not enough frames in the
film.
Set the film with more frames than
#### in the carrier.
Insufficient number of frames
Use a film having more than five
frames.
W-4872
Ejecting film.
Film remaining
–
W-4873
Eject film.
Set the film.
Remaining film ejected when film
insertion is required.
Insert a film.
W-4874
Please install the calibration mask.
Calibration mask not installed
(Causes of the error message)
1. Calibration mask not installed or
improperly seated
2. Faulty mask sensor
1. Install the mask correctly.
2. Replace the MSB23 circuit board.
1-4875
Update the CPZ CB parameters.
Insert the floppy disk.
Press [OK] to write the parameters to
the CB memory, and also its backup
data is written in the hard disk.
[FD reading] button of CPZ was
clicked in “Scanner Parameter Check/
Update”.
Click [OK].
W-4876
Reading parameters from the CPZ
CB failed.
Check the floppy disk.
FD data is abnormal or not found
after [FD reading] button of CPZ was
clicked in “Scanner Parameter Check/
Update”.
(Causes of the error message)
1. FD not inserted
2. No piezoelectric actuator
parameters in FD
3. File size different
1. Insert the FD.
2. Insert the parameter FD.
3. Insert the parameter FD.
I-4877
Insert a film.
[Run] button was clicked in “Focus
Position Calibration” for MFC10AY.
Insert a film.
I-4878
Save the parameters for CB memory
in the hard disk.
[Store] button was clicked in “Scanner
Parameter Check/Update”.
Click [OK].
I-4879
Write the backup parameters in the
hard disk to the CB memory.
[Reading] button was clicked in
“Scanner Parameter Check/Update”.
Click [OK].
W-4880
An incorrect diffusion box is installed.
Install the correct diffusion box.
Incorrect combination of diffusion box
and mask
Set the correct combination.
W-4881
An incorrect film mask is installed.
Install the correct film mask.
Incorrect combination of diffusion box
and mask
Set the correct combination.
W-4882
Wrong combination of film mask and
diffusion box.
Check combination of film mask and
diffusion box.
Incorrect combination of diffusion box
and mask
Set the correct combination.
No.
Message
Factor
Actions