3-23
3.2 Messages and Actions
3
W-2314
Updating backup memory in printer
failed.
Check parameter file.
File acquisition has failed while
connecting to the scanner.
(Causes of the error message)
1. Insufficient number of printer/
processor parameter files are
stored in the scanner.
2. Installation has been performed
incompletely.
1. Load the machine parameters
from the FD.
2. Reinstall system software.
W-2315
Communication error occurred
between scanner and Printer.
Refer to manual for guidance.
Communication between the scanner
and printer/processor has interrupted
more than 30 seconds.
(Causes of the error message)
1. Poorly connected or broken 1394
(interface) cable
2. Poorly connected or broken 1394
grounding clamp
3. Faulty scanner GIE23 circuit board
1. Connect the cable correctly, or
repair or replace it.
2. Connect the clamp correctly, or
repair or replace it.
3. Replace GIE23 circuit board on
the scanner.
E-2331
Image control box cooling fan(F620)
abnormal.
Shut down scanner with emergency
button and restart it. If problems
persist, consult your technical
representative.
Rotation of the image control section
cooling fan (F620) is not detected.
(Causes of the error message)
1. Poorly connected or broken
harness between the image
control section cooling fan (F620)
and GMC4 on the GMC23 circuit
board
2. Faulty F620
3. Faulty GMC23 circuit board
1. Connect the harness correctly, or
repair or replace it.
2. Replace F620.
3. Replace the GMC23 circuit board.
E-2332
Image control box cooling fan(F620)
abnormal.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Rotation of the image control section
cooling fan (F620) is not detected.
(Causes of the error message)
1. Poorly connected or broken
harness between the image
control section cooling fan (F620)
and GMC4 on the GMC23 circuit
board
2. Faulty F620
3. Faulty GMC23 circuit board
1. Connect the harness correctly, or
repair or replace it.
2. Replace F620.
3. Replace the GMC23 circuit board.
E-2333
Temperature in circuit board(GMC23)
abnormal.
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Although the rotation of the image
control section cooling fan (F620) is
detected, the temperature of the
GMC circuit board exceeds 45 °C.
(Causes of the error message)
1. Ventilation holes in the GMC box
are blocked by with foreign matter.
2. Faulty GMC23 circuit board
1. Remove foreign matter.
2. Replace the GMC23 circuit board.
E-2334
Communication error occurred in
printer(GMC23 CTL23).
Shut down scanner with emergency
stop button and restart it. If problems
persist, consult your technical
representative.
Communication timeout between the
GMC23 and CTL23 circuit boards
(Causes of the error message)
1. Poorly connected or broken
harness between the GMC23 and
CTL23 circuit boards
2. After data transmission, the
GMC23 cannot receive any
responses from the CTL23.
3. After data transmission, the CTL23
cannot receive any responses
from the GMC23.
1. Connect the harness correctly, or
repair or replace it.
2. Replace the CTL23 circuit board.
3. Replace the GMC23 circuit board.
No.