3-141
3.2 Messages and Actions
3
W-7051
Film remains in IX240 feeding lane.
Remove carrier and then film.
Feed lane was changed during
feeding IX240 film in NC100AY.
(Causes of the error message)
1. Changed feed lane during
scanning
2. Faulty IX240 feed lane position
sensor (D130) or harness
3. Faulty CYA23 circuit board
1. Remove the film.
2. Replace the sensor or harness.
3. Replace the circuit board.
W-7052
Feeding of film failed.
Remove carrier and then clean
feeding lane.
NC100AY IX240 film insertion error
(Causes of the error message)
1. IX240 strip film leading end does
not reach to first roller.
2. Blocked film outside of carrier
3. Faulty IX240 perforation sensor
(D117L/P) or harness
4. Faulty JNC23 circuit board or
harness
5. Faulty feed motor (M101), feed
drive system or harness
1. Insert the film into the carrier as for
as it will go.
2. Remove the cause of blocking.
3. Replace the sensor or harness.
4. Replace the circuit board.
5. Replace the motor, feed drive
system or harness.
W-7053
Film rupture.
Remove carrier and then film.
Hole was detected in IX240 film by
NC100AY.
(Causes of the error message)
1. Hole in film
2. Faulty IX240 perforation sensor
(D117L/P) or harness
3. Faulty flexible cable
4. Faulty JNC23 circuit board
5. Faulty CYA23 circuit board
1. Remove the film.
2. Replace the sensor or harness.
3. Reconnect or replace the cable.
4. Replace the circuit board.
5. Replace the circuit board.
W-7054
Film remains in IX240 feeding lane.
Remove carrier and then film.
NC100AY IX240 film existing
installation error
(Causes of the error message)
1. IX240 film remaining
2. Dust or dirt adhered to TSB sensor
(D116) glass
3. Faulty IX240 TSB sensor (D116)
or harness
4. Faulty flexible cable
5. Faulty JNC23 circuit board
6. Faulty CYA23 circuit board
1. Remove the film.
2. Clean the glass.
3. Replace the sensor or harness.
4. Reconnect or replace the cable.
5. Replace the circuit board.
6. Replace the circuit board.
W-7055
Film remains in IX240 feeding lane.
Remove carrier and then film.
NC100AY IX240 film existing
installation error
(Causes of the error message)
1. IX240 film remaining
2. Dust or dirt adhered to IX240
perforation sensor (D117) glass
3. Faulty IX240 perforation sensor
(D117) or harness
4. Faulty flexible cable
5. Faulty JNC23 circuit board
6. Faulty CYA23 circuit board
1. Remove the film.
2. Clean the glass.
3. Replace the sensor or harness.
4. Reconnect or replace the cable.
5. Replace the circuit board.
6. Replace the circuit board.
W-7056
An error occurred in cartridge door.
Install the carrier again.
If problems persist, consult your
technical representative.
NC100AY IX240 door motor
initialization error
(Causes of the error message)
1. Faulty door motor (M104) or drive
system (damaged gear or rack/
improper engagement)
2. Faulty door motor (M104) or
harness
3. Faulty door open/close sensor
(D120) or harness
4. Faulty CYA23 circuit board
1. Replace the motor or damaged
parts.
2. Replace the motor or harness.
3. Replace the sensor or harness.
4. Replace the circuit board.
No.
Message
Factor
Actions
TSB sensor = Leading end/trailing end/bar code sensor