Manual ResistTel IP2 / IP152
Page 409
ExResistTel IP2 / IP154
Environmental conditions
Ambient operating temperature
-40°C…+70°C
Transport and storage temperature
-40°C…+80°C
Conformities
Degree of protection
IP66 acc. to EN/IEC 60529
Degree of protection against external
mechanical impacts
IK09 acc. to EN/IEC 62262
Declaration of Conformity
Directive 1999/5/EU (R&TTE)
Directive 2004/108/EG (EMC)
Directive 2006/95/EG (low voltage)
Restriction of Hazardous Substances
(ROHS)
Directive 2011/65/EG
Waste Electrical and Electronic
Equipment (WEEE)
Directive 2012/19/EG
EAR registration no.: DE 58023377
User interface
Web-interface (administration)
English
Telephone (user menu)
16 languages adjustable
9.2
Explosion Proof Telephones
Connection data
Power supply
Power over Ethernet refer to IEEE
802.3af or external power supply
Voltage PoE
48V DC (Min. 44V, Max. 57V). The power
has to be transmitted at 10/100 Mbit/s
Ethernet connections only with the
unused pairs of data lines.
PoE
Class 0
Voltage external power supply
19.2 V – 52.8 V DC
Power requirement
12.95 W
Switching power relays
250 V, 5 A, 100 VA AC
230 V, 0.5 A, 100 W DC
50 V, 1 A, DC
30 V, 5 A, 100 W DC
Connection Ethernet
Terminals (10/100 Mbit/s)
Ringing volume
Max. 95 dB(A) in 1 m distance
Summary of Contents for ExResistTel IP2/IP154
Page 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Page 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Page 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Page 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...