Page 262
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
At the start of Vision Sensor Device Manager or by click to the button “Find” the sensor is listed in
window “Active sensors”. By click to the button “Set” the following dialog starts.
5.6.2.2 Setting of IP and name
Fig. 272: Setting of IP and name
Here the IP address of the SBS and it´s name is set.
If here a name is set which shall be used permanently, the identical name must be used in the PLC as well.
Caution: these settings are active not before a reboot of the sensor.
Close this dialog with “Set”
Important conditions:
Independent from which possibility is used to do the settings, for a properly working Profinet
communication it´s neccessary:
l
The SBS name must be identical in PLC and sensor
l
The IP address of SBS and PLC must correspond (same address range)
IP address and name of the SBS can be set in different ways:
l
Either via SBS software Vision Sensor Device Manager, or
l
Via PLC interface, here Siemens TIA.
l
The name must be DNS compatible. That means: .
l
Hostnames may only consist of the characters 'a'-'z', '0'-'9', '-' and '.'. (lower case only)
l
The Character '.' may just occure as divider between labels in domain names.