Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
4.6.4 Output of inspection results
Here you define the assignment and logical connection of the digital signal outputs as well as the interfaces
and output data of your SBS .
Output signals (Digital outputs / Logic) (Page 178)
Timing, Digital outputs (Page 184)
Telegram, Data output (Page 189)
4.6.4.1 I/O mapping
Here the following settings can be made:
1. Definition, if I/O is used as an input or output (Pin 05 - 08, can be used as input or output)
2. Assignment of functionality to inputs and outputs. In the list-box there can be seen and selected all
available functions for this input or output. Some functions can be assigned only to one special input
or output (e.g. HW/Trigger).
Fig. 170: Output, I/O Mapping
4.6.4.1.1 Functions of inputs
Function
Description
H/W Trigger
Hardware Trigger (only on pin 03 WH available)
Encoder A+
Input for encoder, Track A+ (only on pin 10 VT available)
Encoder B+
Input for encoder, Track B+ (only on pin 05 PK available)
Enable Trigger
Enable or disable trigger signals (input needs a minimum signal length of 2ms before
raising trigger signal).
Job 1 or 2
Job change between Job 1 and Job 2, depending on status of this input. Low = Job 1,
High = Job 2.
Job 1 … N
Job change by pulses on one input
Teach
temporary /
Teaching of all detectors.
Rising edge on this input and trigger start teaching.
Summary of Contents for SBSC-EN