Page 338
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
Truncated
1
F = Code
complete, P =
Code truncated
Code truncated
Checksum
3
XOR checksum of all bytes in telegram
Trailer
1 - max.
8
User defined, max.
8 characters
End of string (Trailer)
*1) All detector-specific data with decimal places are transmitted as whole numbers (multiplied by 1000)
and must therefore be divided by 1000 after receipt of data.
8.1.2 Serial communication BINARY
Data format of commands and data output
Communication settings
Communication
Ethernet
RS422
To Sensor, Command
Selectable in Tab: Protocol (Binary or ASCII)
From Sensor, Data output
Selectable in Tab: Protocol (Binary or ASCII)
Commands to sensor in BINARY
Trigger (Binary) Request string to sensor
Byte
no.
Data type
Contents Significance
1
Unsigned
Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x05
5
Unsigned
Char
0x01
Trigger command, (simple trigger without index, via port 2006)
Trigger (Binary) Answer string from sensor
Byte
no.
Data type
Contents Significance
1
Unsigned
Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x07
5
Unsigned
Char
0x01
Trigger command, (response to trigger without index, via port 2006. If defined:
result data without index via port 2005)
6
Unsigned
0x00
Error code, 0 = Pass, 1 = Fail
Summary of Contents for SBSC-EN