Page 220
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
Fig. 218: Data output, Ethernet
In the example the Ethernet interface in the parameter field at the bottom in tab “interfaces” is activated
by marking the checkbox. The default settings for input port (IN) = 2006 and output port (OUT) = 2005
remain as they are in this example. Of course here any other settings can be chosen to do a setup which
fit to your network environment. If necessary please contact your network administrator.
Step 2:
In tab „Telegram“ the payload which should be transferred via Ethernet port 2005 are set up.
In this example it is:
l
Start: „010“
l
Overall result of detector 1
l
Trailer: „xxx“
l
As format „ASCII“ is defined, that makes traceability easier. The function with other payload data or
in binary format works analogue to this example and to the here made settings.
Fig. 219: Data output, configuration of output data
Step 3: