l
l
Detector Color area, Color select (Page 166)
l
Detector Color list (Page 169)
l
Detector Color value (Page 164)
Create new detector:
1. Click on “New" button under the selection list in the configuration window and select the type of
detector required. A new detector entry appears in the selection list.
2. Edit the name of the detector with a double click on "Name"
Configure detector:
1. Activate the detector in the selection list.
2. Graphically define the appropriate search and parameter zone on the image.
3. Configure the detector by entering/adjusting the parameters in the Parameters /General and if
necessary Advanced tabs in the configuration window. Which tabs are shown depends on the type
of detector selected.
Functions for administration of detectors:
Control
panel
Functions
New
Adds new detector > dialogue box with above-mentioned detector selection list appears
Copy
Copies all parameters from one detector to one or several others. The parameter zones
are not copied. All detectors must be from the same type.
Copy process:
Create all desired destination detectors; they must be of the same type as the source
detector.
Mark source detector in the list
Click to button „copy“
A list occurs, mark all desired destination detectors. (To select several press “Ctrl” key)
Click “Copy” to confirm
Reset
Resets parameters and search and parameter zones of selected detector to standard values
Delete
Deletes the selected detector
Delete all Deletes all the detectors in the list
Information:
"Flash x.x/yyyy.y kB" appears in the bottom corner of the screen, indicating first the memory used by the
current configuration x.x), and the memory available on the sensor (yyyy.y) in kB. Should the memory
used exceed the available memory, this indicator switches to red as there is not enough space for the
current settings on the sensor. In this case you can delete other jobs from the sensor before transfer.
Drawings in the image (yellow, red frames etc.) can be activated or deactivated for any detector or
category in the menu item "View/all drawings". With "View/drawings of current detector only", all
drawings on the screen can be deactivated with the exception of the detector currently being processed.