Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 353
Vision Sensor Manual
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x10
5
Unsigned Char
0x1D
Command Calibration Add Point
6
Unsigned Short
0xXX
List index of calibration point pair
0: attach new point at end of list
>0: overwrite point at existing index position
1: first point in list
7
0xXX
8-11
Unsigned Int
0xXX
World X
12-15
Unsigned Int
0xXX
World Y
Calibration Add Point (Binary) Response string from Sensor
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x0F
5
Unsigned Char
0x1D
Command Calibration Add Point
6
Unsigned Short
0xXX
Error Code
0: Pass
1: Fail
2: Unused
3: Unsufficient parameter data
4: Command rejected, simultaneous module request
received
7
0xXX
8-11
Unsigned Int
0xXX
Image X
12-15
Unsigned Int
0xXX
Image Y
Additional information
Accepted in run mode:
Yes
Accepted in configuration mode:
No
Accepted when Ready Low:
Yes
Status of Ready signal during processing:
Not altered
Supported interfaces
UserApp, Profinet
Necessary settings in requesting job
In "Output/Telegram/Payload" as first and second value
the X- and Y- value of the finding position must be set.
Calibration Calibrate (Binary) Request string to Sensor