Page 342
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
Byte no.
Data type
Contents
Significance
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x08
5
Unsigned Char
0x05
0x06
ID set reference string permanent
ID set reference string temporary
6
Unsigned Short
0xXX
Error Code 00 00 = Pass
Error Code 00 01 = Fail
7
0xXX
8
Unsigned Char
0x0A
Parameter type string
Additional information
Accepted in run mode:
Yes
Accepted in configuration mode:
No
Accepted when Ready Low:
Yes
Status of Ready signal during processing:
Low
*1) Byte No. 7: Command: set reference string / value:
Detector
Function
Command
Length of
following data
Alignment Pattern matching
Threshold Min
Threshold Max
1
2
4
4
Alignment Contour
Threshold Min
Threshold Max
1
2
4
4
Alignment Edge
Threshold Min
Threshold Max
Transition_Horizontal
Transition_Vertical
1
2
101
102
4
4
4
4
Pattern matching
Threshold Min
Threshold Max
1
2
4
4
Contour
Threshold Min
Threshold Max
1
2
4
4
Grey Level
Threshold Min
Threshold Max
GreyMin
GreyMax
1
2
101
102
4
4
4
4
Summary of Contents for SBSC-EN