![Festo SBSC-EN Manual Download Page 127](http://html1.mh-extra.com/html/festo/sbsc-en/sbsc-en_manual_2282529127.webp)
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 127
Vision Sensor Manual
Fig. 124: Boundary BLOB example 2/2: BLOBs are touching inner yellow "Mask" regions, but they are
considered as valid BLOBs yet, as setting "Boundary BLOBs" is ACTIVE now!
4.6.3.8.3.2 Detector BLOB, tab Binarization, Histogram
In this window the Histogram of the grey values inside the yellow ROI, and the chosen thresholds are
shown.
In the here shown example there are clear maxima for fore- and background. The binarization threshold
is adjusted to approx. the center in between.
Fig. 125: Detector BLOB, tab Binarization, Histogram
4.6.3.8.4 Detector BLOB, tab Features
In this tab the features / filter criteria to distinguish between valid and invalid BLOBs/objects can be
defined.
Processing sequence:
1. Step Binarization: List of BLOBs (all valid / green).
2. For each BLOB all selected features are calculated. Use "pipette" function to determine features.
3. For each criteria a range describing the valid BLOBs can be set.