Fig. 232: Data output, Ethernet, Job switch, tool / 3
After the next Trigger command TRG (s. below third line „Send“) the command „TRG“ is displayed again
in the main window in red letters. The SBS responds with „TRGP“ (repetition of command „TRG“ and
„P“ for positive)
In the window left (port2005) the SBS , after switching to Job 1!, now the according result sting which
was defined under Output in Job 1 with „010xxx“!
Function of the both Ethernet- ports for in- and output:
*A: Port 2005, only one direction: Sensor >> PC, all payload data, defined in „Output“
*B: Port 2006, both directions: Sensor <> PC, commands / requests to the SBS , with acknowledge, + all
response data to the request (no payload data !)
Fig. 233: Ethernet- ports
5.1.2 RS422
Numerical data that has been defined under Output/Telegram, now can be transferred in ASCII- or
Binary- format.
Ethernet: The sensor here is the (socket-)“server" and serves the Data via a „server-socket" interface .
This is basically a “program interface”. To read or process the Data a “socket client" (PC, PLC, ....) must
establish a (socket-) connection (active) to the sensor.
Handling, settings
5.1.2.1 RS422 example 1: Data output from SBS to PC / PLC, and
commands (requests) to the SBS
With response / Data output from SBS