Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 35
Vision Sensor Manual
Fig. 22: Vision Sensor Device Manager
Modification of the standard gateway enables operation in different sub-networks. Only alter this setting
after consultation with your network administrator. Automatic integration of a new computer or sensor
in the existing network without manual configuration is possible through DHCP. Normally, automatic
supply of IP address must only be set on the sensor, the client. When the sensor is started in the
network, it can obtain the IP address, net mask and gateway from a DHCP server. Activation of DHCP
mode is carried out via the “Set” button by activating the checkbox “DHCP“. As one and the same SBS
can thus have different IP addresses at different times, a sensor name must be attributed when activating
the DHCP. Should several SBS s be in one network, different names must be used.
Fig. 23: SBS IP Setup
If a SBS with DHCP is switched on in a network without a DHCP server, the SBS automatically sets the
IP address to 0.0.0.0. This can be the case, e.g. in the case of power/server failure or the restart of the
system after shutdown as the DHCP server may boot slower than the SBS . Make sure that the SBS is
only switched on when the DHCP server is available.
Summary of Contents for SBSC-EN
Page 1: ......