Page 250
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
Fig. 261: Ram Disk Sensor via Explorer
A further possibility to access the data on the sensor e.g. is:
Use Windows command „cmd“ in Start/Run to open a DOS- window. Process the following commands.
The password in factory setting is „user“.
l
First change to the folder on the PC where the data should be stored.
l
With ftp „IP_Adr_SBS“ a connection to SBS is established.
l
User name: user
l
Password: user
l
Go to folder: /tmp/results on the SBS.
l
There are the both files: image.bmp and results.csv (if in Output/Telegram a data string was defined),
as image and result data of the latest evaluation.
l
With command „get image.bmp“, or. „get results.csv“ the files are copied to the selected folder on the
PC