4.6.3.9.3 Detector Caliper, tab Distance
In this tab all parameters of the searched for distance can be set.
Fig. 133: Detector Caliper, tab Distance
Parameter Function
Distance
Distance in pixels, with two limits for tolerance band
Blue bar: current distance value
Distance
mode
For each search stripe one touching point is calculated. If the number of search stripes >1
there a different possibilities how the final result is calculated.
- Maximum: The touching point which represents the longest distance is selected.
- Minimum: The touching point which represents the smallest distance is selected.
- Mean (Average): All touching points are arithmetically averaged. If there are outliers these
are also used for the calculation, and do influence the result.
- Median: The values of the touching point are sorted ascending and the middle (central)
value in the list is chosen. Outliers do not influence the result.