4.6.4.2.6 Input, Repeat Mode Enable, in Freerun
Fig. 179: Input, Repeat Mode Enable, with Trigger
4.6.4.3 Output signals (Digital outputs / Logic)
In this tab, you define the switching behaviour and logical connection of the digital outputs. Number of
outputs depends from settings in tab IO mapping. Additionally an IO-extension can be connected over the
serial interface.
Fig. 180: Output, tab digital output
Description of different cases with a signal diagram.
For each pin (output) there are the following possibilities:
Parameter Function
Overall job
result
No physical output, effects recorder, statistics and archiving functions
Invert
Invert total result for this pin (output)
Mode
Standard: combine several detectors by logical expressions like AND (&) / OR (|) / NOT
(!) to one logical expression.
Advanced: Free edit of logical expression.