Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 193
Vision Sensor Manual
SBS sensor opens always two (socket-) communication ports (default: 2005 + 2006).
l
2005 = Data port for sending of numerical results.
l
2006 = Command port for receiving of commands.
At a time only one (socket-) client (PC or PLC) can be connected to a port.
Recommendations:
Existing socket connections have only to be reconnected, if an error occurred (on ports 2005 + 2006)
(e.g.: PLC or client in stop mode or error mode, etc.). During normal operation there is no need to
reconnect existing connections.
Ethernet data handling: Especially if several SBS are used Ethernet should be preferred.
Please see also installed help:
...:\Program files\Festo\SBS R3B Sensor\Utilities\Ethernet\SBS _Ethernet_communication.pdf
Commands to sensor in ASCII
4.6.4.7 Parameters for image transmission
Image transmission and/or the image recorder and the Ram disc can be activated in the Image
transmission tab.
Next topic:
Parameters Archiving (Page 195)
Set image sharpness with the focus setting screw on the back of the SBS .
The symbol “exclamation mark” inside life picture means, that image display / transfer on PC is slower
than image processing on SBS . Not all images are transferred and displayed on the PC. This may cause lost
images during archiving. If this symbol occurs often, PC-programs running in background should be closed
in order to improve PC performance.
Parameters
Functions and setting possibilities
Vision Sensor
Visualisation
Studio
Transmission of images to Vision Sensor Visualisation Studio can be switch on and
off (Off increases the speed of SBS ).
- Off: no images are transmitted to Vision Sensor Visualisation Studio
- On: images are transmitted. Pre-processing filters do not effect the images. (But, if
activated, Arrangement filters do effect the transmitted images!)
- On (with Pre-processing): Images are transmitted, all activated Pre-processing and
Arrangement filter do effect the image.
Image recorder
Storage of max. 10 images in the sensor's internal ring buffer. Setting possibilities via
pop-up menu: Off, Any, Pass, Fail.
Ram disk
Storage of last image in ram memory, this image can be taken by a FTP-client.
Ram disk
Settings: Off, Any, Pass, Fail.
The image is stored under name "image.bmp" in folder /tmp/results/ .
Parameters for FTP-client: user "user", password "user"
Example Windows Console:
Summary of Contents for SBSC-EN