Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 253
Vision Sensor Manual
Fig. 263: Job- switch binary
5.3.1.3 Job 1..n via pulses
To switch between job´s with function “Job 1..n” any input can be set up with this function in Vision
Sensor Configuration Studio/Output/I/O mapping. Only possible if Ready = High. After the last impulse
(+50ms) Ready is set to low. Impulses are counted until the first delay of >= 50ms and then switches to
the appropriate job. Ready remains low until switch-over to the new job occurs. If the option “Job change
confirm” is used, this signal occurs after the job change, and hereafter Ready is set high again. During Job
Change over binary inputs there must not be sent any trigger signal. Pulse length for job change should be
5 ms pulse and 5 ms delay. S. also chap.
/ Function of inputs ff.
If possible job change should be made by binary coded signals like in chap.
Job 1… 31 via binary bit pattern
,
this is the faster way.
5.3.2 Job switch via Ethernet
s. chap.
Ethernet example 2.1 command job switch from PC/PLC to SBS
5.3.3 Job switch via Serial
s. chap.
RS422 example 1.1: command Job switch from PC / PLC to SBS
5.3.4 Job switch via Vision Sensor Visualisation Studio
In the application Vision Sensor Visualisation Studio a job switch can be made, or completely new job set´s
can be uploaded.
Summary of Contents for SBSC-EN
Page 1: ......