Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 347
Vision Sensor Manual
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x09
5
Unsigned Char
0x0E
0x0F
Command set shutter temporary
Command set shutter permanent
6
Unsigned Int
0xXX
Shutter value (in microseconds)
7
0xXX
8
0xXX
9
0xXX
Set Shutter (Binary) Response String from Sensor
Byte No.
Data Type
Contents
Significance
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x07
5
Unsigned Char
0x0E
0x0F
ID set shutter temporary
ID set shutter permanent
6
Unsigned Short
0x00
Error Code 00 00 = Pass
Error Code 00 01 = Fail
7
0xXX
Additional information
Accepted in run mode:
Yes
Accepted in configuration mode:
No
Accepted when Ready Low:
Yes
Status of Ready signal during processing:
Pulled Low
Get Shutter (Binary), Request string to Sensor (since version 1.6.5.3)
Byte No.
Data type
Contents
Significance
1
Unsigned int
0x00
Length of telegram
2
0x00
3
0x00
4
0x05
5
Unsigned Char
0x17
Request ID, Get shutter
Summary of Contents for SBSC-EN