Page 356
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x17
5
Unsigned Char
0x20
Command Calibration Validate
6
Unsigned Short
0xXX
Error Code
0: Pass
1: Fail
2: Unused
3: Unsufficient parameter data
4: Command rejected, simultaneous module request
received
7
0xXX
8-9
Unsigned Short
0xXX
Current highest point pair index
10-13
Unsigned Int
0xXX
RMSE (Root Mean Square Error)
14-17
Unsigned Int
0xXX
Mean
18-21
Unsigned Int
0xXX
Max
22-25
Unsigned Int
0xXX
Min
Additional information
Accepted in run mode:
Yes
Accepted in configuration mode:
No
Accepted when Ready Low:
Yes
Status of Ready signal during processing:
Not altered
Supported interfaces
UserApp, Profinet
Set Gain (Binary) Request string to Sensor
Byte No.
DataType
Content
Significance
1
Unsigned Int
0x00
Length of telegram
2
0x00
3
0x00
4
0x0A
5
Unsigned Char
0x1B
Set Gain
6
Unsigned Char
0xXX
1 = Permanent
0 = Temporary
Summary of Contents for SBSC-EN