Fig. 213: Archiving configuration
Parameter Function
Path for
archiving
Directory in which archived file(s) are stored.
Settings,
Automatic
Start
Starts archiving automatically after start of Vision Sensor Visualisation Studio.
Settings,
Archive
image
circularly
Activates cyclic overwriting of oldest images if limitation of storage is reached.
Settings,
Limitation
(max.)
In this drop-down menu it is possible to specify which images (all images or only
good or bad images) are to be stored.
Type of
images
Specifies, whether all, good or bad pictures have to be stored.
Graphics, Bar
graph result
Choice of graphics to be archived in the image.
Numerical
results
If "record with" is activated, numerical result data such as coordinate values etc.
are archived in an additional .csv file.
Setting "Legacy" / "Configured" determines the format of storage (.csv). With
"Legacy" *1) the content is predefined, with "Configured" the content can be
defined in "Output/Telegram".
*1) The storage mode "Legacy" is obsolete and only provided for reasons of
backward compatibility. It will be omitted with one of the next versions.
2. Select the required options and confirm your choice with OK.
Start/end archiving:
Click on the button "Archive images" in the "Commands" filed to start or end the archiving function with
the above mentioned settings. The name of the image file currently to be stored appears in the status bar.
Archiving is carried out for as long as the button "Archive images" is pressed.
4.7.5 Statistics
Statistical data from the inspection process is displayed in the Statistics tab in run mode. The statistical
data displayed is identical for all types of detectors:
Parameter
Function
All evaluations
Total number of inspections
Good parts
Number of inspections with result "OK"
Summary of Contents for SBSC-EN
Page 1: ......