MLC 104 IP Plus Series • SIS
™
Pr
ogramming and Contr
ol
78
Command/Response Table for SIS Commands (continued)
Command
ASCII (Telnet)
(host to MLC)
URL Encoded (web)
(host to MLC)
Response
(MLC to host)
Additional Description
Volume adjustment (discrete, for volume mode = 0)
Set the overall output volume
level
14
X*
V
X*
V
Vol
X*]
This command sets a specific volume level for
the audio output either at the display device or
via an optional slaved Extron MediaLink (MLS)
switcher.
X*
= volume level (
0
to
100
).
Default volume =
25
.
When no MLS is detected at the MLS port,
the maximum volume level is limited by the
(
X?
*47#
).
NOTE:
The MLC responds with an E14 (not valid for this configuration) error if you attempt to set a discrete volume
level while the MLC is in increment/decrement volume mode (volume mode 1). This command works only when
the MLC is in volume mode 0. See the 46# volume knob mode SIS command.
Example:
27
V
27
V
Vol
027
]
Example:
set volume to
27
.
Increment the volume
+V
%2BV
Vol
X*]
Increase audio output.
Decrement the volume
-V
%2DV
Vol
X*]
Decrease audio output.
View the volume level
V
V
X*]
Show the output volume.
Volume adjustment (for volume mode = 1)
Increment the volume
+V
%2BV
Vol
X*]
Increase audio output.
NOTE:
The MLC responds with an E14 (not valid for this configuration) error if you attempt to set a discrete volume
level while the MLC is in increment/decrement volume mode (volume mode 1).
Decrement the volume
-V
%2DV
Vol
X*]
Decrease audio output.
View the volume level
V
V
X*]
Show the output volume.
Audio mute
Mute on
1Z
1Z
Amt1
]
Mute all audio outputs. This is
not
the same
as selecting input
0
.
Mute off
0Z
0Z
Amt0
]
Unmute all audio outputs.
View the audio mute status
Z
Z
X%]
Show the status of audio mute.
X%
=
0
(off) or
1
(on).
Front panel security lockout modes (executive modes)
Disable lockout modes
24
0X
0X
Exe 0
]
Default setting. Adjustments and selections
can be made from the front panel in addition
to via RS-232, Telnet, DataViewer,or web
browser.
24
= The MLC responds with an E24 error
(privilege violation) if the connected user is not
logged in at administrator security level.
Enable lockout mode 3
24
3X
3X
Exe 3
]
Lock all front panel selections and
adjustments via MLC, control modules, SCP,
and IR remote. Make selections, changes,
and configure features via RS-232 or web/
Ethernet only. All front panels in the control
system are locked.
Summary of Contents for MLC 104 IP Plus Series