Using these pins and an external switch to trigger digital input:
MLC 104 IP Plus Series
+12 V
Digital
Input
Normally
Open
Switch
GND
2k ohms
SW 2
+5.0 V
CTL
Digital input is triggered
by an external switch
wired between the
I/O pin and ground.
The pull-up resistor to
+5.0 VDC is activated
(switch 2 is
enabled/closed).
Pin 1of the
Host Control port
or the
Pwr Sns pin of the
Projector port
Ground (GND) pin
Using a motorized surface access enclosure to trigger digital input:
SW 1
MLC 104 IP Plus Series
HSA 822M/MS
+12 V
+12 V
Digital
Input
GND
Status
Pin
GND
2k ohms
SW 2
+5.0 V
CTL
CTL
Digital input at the MLC is triggered by a digital output from a motorized
Extron HSA 822M.
A closure to ground (switch 1) occurs when a certain condition is met on the
HSA. This closure to ground triggers the MLC.
The MLC must have the pull-up resistor to +5.0 VDC activated (switch 2 is
enabled/closed).
Ground (GND) pin
Pin 1of the
Host Control port
or the
Pwr Sns pin of the
Projector port