MLC 104 IP Plus Series • Operation, Features, and Cabling
26
MLC 104 IP Plus Series
+12 V
+12 V
2k
Ohms
LED
Digital
Output
GND
CTL
SW 1
Pin 1
The digital
output pin
drives an LED
using the
+12 VDC
output of the
controller as a
voltage source.
The LED lights
only when the
I/O pin is set to
“on” (switch 1
is closed).
NOTE:
The digital I/O pin is capable of sinking a maximum of 250 mA from
12 VDC, max.
Lamp
MLC 104 IP Plus Series
+12 V
+12 V
Digital
Output
+12 V Out
GND
CTL
SW 1
The digital output
pin drives an
incandescent
lamp using the
+12 VDC output
of the controller
as the voltage
source.
The lamp lights
only when the
I/O pin is set to
“on” (switch 1 is
closed).
NOTE:
The digital I/O pin is capable of sinking a maximum of 250 mA from
12 VDC, max.
4
MLS RS-232 connector
— To control an optional Extron switcher or other RS-232
controllable device, connect a cable between this 3.5 mm direct insertion captive screw
connector and the RS-232 port of the other device. By default this port supports any
Extron switcher without additional drivers. If it is used to control other products,
additional device drivers may be required.
NOTE:
The commands issued from this port are
standard Extron SIS
™
commands, and they
follow the typical Extron RS-232 protocol:
• 9600 baud
• no parity
• 8 data bits
• no flow control
• 1 stop bit
Supported Extron Devices
MLS 406
MLS 608 D
MLS 406MA
MLS 608 D MA
MLS 406SA
MLS 608 D SA
MLS 506
PVS 305SA IP
MLS 506MA 70 V MLA VC10 Plus
MLS 506SA